Product Profile:
 |
General Description:
A water-based primer/sealer.
|
 |
Common Usage:
This primer is typically used under alkyd and waterborne enamels on new
sheetrock walls. It can also be used as a wallpaper sizing.
|
 |
Color: White |
 |
Finish: Flat |
Coating Systems:
 |
Primer Coats:
Typical topcoats include Anchor #P-100 series, #P-200 series, #P-300 series,
#P-400 series, #P-600 series, or #P-700 series. Consult your Anchor
representative for specific job recommendations.
|
Surface Preparation:
 |
The surface must be free of all dirt, grease, or other contaminants,
loose or failing paint, chalking surfaces, rust or moisture.
|
Technical Data:
 |
Volume Solids: 33.68% |
 |
Recommended Thickness: 1.6-2.0 mils dry per coat. |
 |
Drying Time:
| Temperature |
 |
To Touch |
 |
To Recoat |
 |
| 75 F / 55% R.H. |
|
30 Minutes |
|
1 Hour |
|
| (Cooler temperatures and higher humidity will lengthen drying time) |
|
 |
Architectural and Industrial Maintenance Category: Flat coatings, Interior |
 |
Maximum Allowable V.O.C.: 2.1 lbs./gallon (250g/l) |
 |
Actual V.O.C.: .42 lbs./gal. (50 g/l) (1.09 lbs./gal. minus water + exempt materials) |
 |
Theoretical Coverage:
540 sq. ft./gallon @ 1 mil dry, assuming no application loss. Coverage will
depending on the surface texture and the application technique.
|
 |
Packaging: 55 Gallon drums, 5 Gallon pails and 1 Gallon cans
|
 |
Storage Temperature:
| Minimum 35 F |
 |
Maximum 110 F |
|
 |
Physical Properties:
 |
Abrasion: |
 |
Fair |
 |
Flexibility: |
 |
Good |
 |
Weather: |
 |
Interior Use Only |
|
 |
Health & Safety:
Refer to the front of this manual, the product label itself, and your Anchor representative concerning a Material Safety Data Sheet for complete information on this product. |
Application:
 |
Coverage Rates Per Coat:
 |
|
 |
Dry Mils |
 |
Wet Mils |
 |
Sq.Ft./Gal. |
 |
Suggested: |
|
1.8 |
|
5.3 |
|
300 |
 |
Minimum: |
|
1.6 |
|
4.8 |
|
338 |
 |
Maximum: |
|
2.0 |
|
5.9 |
|
270 |
|
 |
Mixing: Stir thoroughly, making sure no pigment remains on the bottom of the can.
|
 |
Thinning: Thin only if necessary up to one pint of water per gallon.
|
 |
Surface Temperature:
| Minimum 40 F |
 |
Maximum 90 F |
| The surface should be dry and the relative humidity should be less than 85%.
|
|
 |
Application Equipment:
 |
Airless Spray
 |
Pressure: |
 |
1800-2400 psi |
 |
Tip: |
 |
.015"-.017" |
|
 |
Conventional Spray
|
 |
 |
Air Pressure: |
 |
40-70 psi. |
 |
 |
Fluid Pressure: |
 |
10-20 psi |
 |
Brush: Use high quality synthetic or nylon bristle brushes. |
 |
Roller: Use a 3/8" or a 1/2" lambswool cover |
|
 |
Cleanup: Use soap and water. |
 |
Application Considerations:
This coating can be applied by brush, spray or roller.
Keep from freezing. Always apply into rather than away from the wet edge,
overlapping each pass 50%.
|
Limited Warranty: The technical data on this label or on other data is true and accurate to the best of our knowledge. We guarantee our products to conform to ANCHOR PAINT MFG. CO. quality control standards. Due to misuse in handling, storage, application and workmanship or variables such as weather or surface integrity that are beyond our control, Anchor Paint does not authorize any representative to make any warranty or merchantability of fitness of this product. Any liability whatsoever of Anchor Paint Mfg. Co. to the buyer or user of this product is limited to the purchaser’s cost of the product itself.
|