Product Profile:
 |
General Description:
An oxidative long oil, spar resinous coating.
|
 |
Common Usage:
For interior and exterior use offering resistance to water, heat,ultra-violet rays,
etc. This is a very white, bright, leafing type aluminum that is highly
recommended for tanks, derricks, water towers, structural steel, piping or
wherever a high grade aluminum is required.
|
 |
Color: Aluminum |
 |
Finish: Metallic |
Coating Systems:
 |
Primer Coats:
Use Anchor #1730 Series Rust Inhibitive Primers or #472 Gray Fast Dry
Primers. This product requires an A.I.M. compliant primer when not used in
shop applications, such as Anchor #1630 series or #B-7911. Consult your
Anchor representative for specific job recommendations.
|
Surface Preparation:
 |
At minimum, the surface should be thoroughly degreased in accordance with
SSPC-SP1. All burrs should be removed and sharp edges or rough weld
seams should be ground down. Where weathered steel is applicable and
where the substrate has reached rust grade, appropriate chemical cleaning or
blasting will be necessary. This product is designed to be applied over alkyd
primer or intermediate coats. When not feasible, this product can be applied
directly over the substrate making sure a maximum millage is achieved.
|
Technical Data:
 |
Volume Solids: 40.87% |
 |
Recommended Thickness: 1.6-2.0 mils dry per coat. |
 |
Drying Time:
| Temperature |
 |
To Touch |
 |
To Recoat |
 |
| 75 F / 55% R.H. |
|
20 Minutes |
|
24 Hours |
|
| (Cooler temperatures and higher humidity will lengthen drying time) |
|
 |
Architectural and Industrial Maintenance Category: Metallic Pigmented |
 |
Maximum Allowable V.O.C.: 4.2 lbs./gal. (500 g/l) |
 |
Actual V.O.C.: 3.94 lbs./gal. (473 g/l) |
 |
Theoretical Coverage:
656 sq. ft./ gallon @ 1 mil dry, assuming no application loss. Coverage will
vary depending on the surface texture and application technique.
|
 |
Packaging: 5 Gallon pails, 1 Gallon cans, and quart (1/4 gallon) cans |
 |
Storage Temperature:
| Minimum 20 F |
 |
Maximum 110 F |
|
 |
Chemical Resistance:
 |
Alkalis: |
 |
Poor |
 |
Acids: |
 |
Good |
 |
Water: |
 |
Excellent |
|
 |
Health & Safety:
Refer to the front of this manual, the product label itself, and your Anchor representative concerning a Material Safety Data Sheet for complete information on this product. |
Application:
 |
Coverage Rates Per Coat:
 |
|
 |
Dry Mils |
 |
Wet Mils |
 |
Sq.Ft./Gal. |
 |
Suggested: |
|
1.8 |
|
4.4 |
|
364 |
 |
Minimum: |
|
1.6 |
|
3.9 |
|
410 |
 |
Maximum: |
|
2.0 |
|
4.9 |
|
328 |
|
 |
Mixing: Stir thoroughly, making sure no pigment remains on the bottom of the can. |
 |
Surface Temperature:
| Minimum 40 F |
 |
| The surface should be dry and the relative humidity should be less than 85%. |
|
 |
Application Equipment:
 |
Airless Spray
 |
Pressure: |
 |
1200-2200 psi |
 |
Tip: |
 |
.011"-.015" |
|
 |
Conventional Spray
|
 |
 |
Air Pressure: |
 |
40-70 psi |
 |
 |
Fluid Pressure: |
 |
10-20 psi. |
 |
Brush: Use high quality natural china bristle brushes. |
 |
Roller: Use 1/4" synthetic nap covers. |
|
 |
Cleanup: Use Anchor #J-1131 synthetic thinner. |
 |
Application Considerations:
Brush, spray, or roll. Apply in wet coats to avoid dusting. When spraying,
use a cross-hatch method, overlapping each pass 50%. Clean system
thoroughly before and after each use. On a derusted surface, the application
of a dry film thickness of at least 2 mils is recommended.
|
Limited Warranty: The technical data on this label or on other data is true and accurate to the best of our knowledge. We guarantee our products to conform to ANCHOR PAINT MFG. CO. quality control standards. Due to misuse in handling, storage, application and workmanship or variables such as weather or surface integrity that are beyond our control, Anchor Paint does not authorize any representative to make any warranty or merchantability of fitness of this product. Any liability whatsoever of Anchor Paint Mfg. Co. to the buyer or user of this product is limited to the purchaser’s cost of the product itself.
|