Product Profile:
 |
General Description:
This is a fast drying alkyd enamel that provides a decorative and durable mar-
resistant coating. Due to its low luster and dense film, it will not hold dirt as
flat materials will do.
|
 |
Common Usage:
Areas such as ducting, joists and ceilings where the fallout or overspray dries
within a few feet so that it does not adhere to unprotected surfaces. This
product is not intended for direct exposure to weather.
|
 |
Color: White |
 |
Finish: Low Sheen |
Coating Systems:
 |
Primer Coats:
Use Anchor #472 Gray, #2653 Red Fast Dry Primers or direct to metal.
Consult your Anchor representative for specific job recommendations.
|
Surface Preparation:
 |
Surface must be dry and free of all dirt, grease, oil, failing paint, etc. On
previously painted surfaces, test for lifting by applying in a small area and
allowing to cure while watching for wrinkling or seperating. Designed to be
applied over primer. When not feasible, it may be applied directly over
substrate making sure a maximum recommended millage is obtained.
|
Technical Data:
 |
Volume Solids: 35.64% |
 |
Recommended Thickness: 2.0 mils dry minimum. |
 |
Drying Time:
| Temperature |
 |
To Touch |
 |
To Recoat |
 |
| 75 F / 55% R.H. |
|
20 Minutes |
|
1 Hour |
|
| (Cooler temperatures and higher humidity will lengthen drying time) |
|
 |
Architectural and Industrial Maintenance Category: Not Intended for Residential Use; Shop Use Only |
 |
Actual V.O.C.: 4.53 lbs./gal. (543.6 g/l) |
 |
Theoretical Coverage:
572 sq. ft./gallon @ 1 mil dry, assuming no application loss. Coverage will
vary depending on surface texture and application technique.
|
 |
Packaging: 5 Gallon pails, and 1 Gallon cans |
 |
Storage Temperature:
| Minimum 20 F |
 |
Maximum 110 F |
|
 |
Chemical Resistance:
 |
Alkalis: |
 |
Poor |
 |
Acids: |
 |
Good |
 |
Water: |
 |
Good |
|
 |
Health & Safety:
Refer to the front of this manual, the product label itself, and your Anchor representative concerning a Material Safety Data Sheet for complete information on this product. |
Application:
 |
Coverage Rates Per Coat:
 |
|
 |
Dry Mils |
 |
Wet Mils |
 |
Sq.Ft./Gal. |
 |
Suggested: |
|
2.0 |
|
5.6 |
|
286 |
 |
Minimum: |
|
2.0 |
|
5.6 |
|
286 |
 |
Maximum: |
|
3.0 |
|
8.4 |
|
190 |
|
 |
Mixing: Stir thoroughly, making sure no pigment remains on the bottom of the can. |
 |
Thinning: Use Anchor #J-1131 or #J-34 Fine Finish Blend. |
 |
Surface Temperature:
| Minimum 50 F |
 |
Maximum 110 F |
| The surface should be dry and the relative humidity should be less than 85%. |
|
 |
Application Equipment:
 |
Airless Spray
 |
Pressure: |
 |
1200-2200 psi |
 |
Tip: |
 |
.011"-.015" |
|
 |
Conventional Spray
|
 |
 |
Air Pressure: |
 |
40-70 psi |
 |
 |
Fluid Pressure: |
 |
10-20 psi |
|
 |
Cleanup: Use Anchor #J-1131 synthetic thinner. |
 |
Application Considerations:
Spray application only. Apply in wet coats to avoid dusting. When spraying,
use cross-hatch method, overlapping each pass 50%. Clean system
thoroughly before and after each use. On a derusted surface the application
of a dry film thickness of at least 2 mils is recommended.
|
Limited Warranty: The technical data on this label or on other data is true and accurate to the best of our knowledge. We guarantee our products to conform to ANCHOR PAINT MFG. CO. quality control standards. Due to misuse in handling, storage, application and workmanship or variables such as weather or surface integrity that are beyond our control, Anchor Paint does not authorize any representative to make any warranty or merchantability of fitness of this product. Any liability whatsoever of Anchor Paint Mfg. Co. to the buyer or user of this product is limited to the purchaser’s cost of the product itself.
|