Product Profile:
 |
General Description:
A low V.O.C., high solids, penetrating oil/ alkyd rust inhibitive primer. |
 |
Common Usage:
Typical substrates include structural steel, storage tanks, steel fences, machinery and equipment, bridges and towers. |
 |
Color: #1603-Gray, #1622-Red and #1630-White |
 |
Finish: Low Sheen |
Coating Systems:
 |
Finish Coats:
Suitable topcoats include alkyds, modified alkyds, and water-borne coatings. Do not apply epoxies, vinyls, or other coatings containing strong solvents such as aromatics or ketones. Each service environment may require a specific coating system or combination of Anchor products. Consult your Anchor representative for specific job recommendations. |
Surface Preparation:
 |
For maximum performance, the recommended substrate should be blasted in accordance with SSPC-SP7. If blast cleaning is not feasible, the substrate should be degreased in accordance with SSPC-SP1. All burrs should be removed and sharp edges or rough weld seams should be ground down. Full use should then be made of mechanical power tools, in conjunction with wire brushing and chipping to remove all loose rust and mill scale to a standard of cleanliness conforming to SP-2 or SP-3. |
Technical Data:
 |
Volume Solids: 56.46% -varies by color |
 |
Recommended Thickness: 1.5-2.0 mils minimum dry. |
 |
Drying Time:
| Temperature |
 |
To Touch |
 |
To Recoat |
 |
| 75 F / 55% R.H. |
|
2 hours |
|
12 hours |
|
| (Cooler temperatures and higher humidity will lengthen drying time) |
|
 |
Architectural and Industrial Maintenance Category: Primers and Undercoaters |
 |
Maximum Allowable V.O.C.: 2.9 lbs./gal. (350 g/l) |
 |
Actual V.O.C.: 2.84 lbs./gal. (340 g/l)- varies by color |
 |
Theoretical Coverage:
907 sq.ft./ gallon @ 1 mil dry, assuming no application loss. Coverage will vary depending on color, the surface texture and application technique. |
 |
Packaging: 55 Gallon drums, 5 Gallon pails, and 1 Gallon cans |
 |
Storage Temperature:
| Minimum 20 F |
 |
Maximum 110 F |
|
 |
Chemical Resistance:
 |
Alkalis: |
 |
Poor |
 |
Acids: |
 |
Good |
 |
Water: |
 |
Excellent |
|
 |
Health & Safety:
Refer to the front of this manual, the product label itself, and your Anchor representative concerning a Material Safety Data Sheet for complete information on this product. |
Application:
 |
Coverage Rates Per Coat:
 |
|
 |
Dry Mils |
 |
Wet Mils |
 |
Sq.Ft./Gal. |
 |
Suggested: |
|
1.75 |
|
3.1 |
|
518 |
 |
Minimum: |
|
1.5 |
|
2.7 |
|
604 |
 |
Maximum: |
|
2.0 |
|
3.5 |
|
453 |
|
 |
Mixing: Stir thoroughly, making sure no pigment remains on the bottom of the can. |
 |
Thinning: This coating is V.O.C. compliant, thin only if necessary with Anchor #J-1131 for spray applications or #J-1112 for brush or roller if permitted by federal, state, and local regulations. |
 |
Surface Temperature:
| Minimum 40 F |
 |
Maximum 110 F |
| The surface should be dry and the relative humidity should be less than 85%. |
|
 |
Application Equipment:
 |
Airless Spray
 |
Pressure: |
 |
1200-2200 psi |
 |
Tip: |
 |
.011"-.015" |
|
 |
Conventional Spray
|
 |
 |
Air Pressure: |
 |
60-80 psi |
 |
 |
Fluid Pressure: |
 |
10-20 psi |
 |
Brush: Use a high quality natural china bristle brush. |
 |
Roller: Use 1/4" synthetic nap covers |
|
 |
Cleanup: Use Anchor #J-1131 synthetic thinner. |
 |
Application Considerations:
The recommended method of application is by airless spray. However, brush, roller or conventional spray may also be used. To avoid dusting, apply in wet coats. On a derusted surface, the application of a dry film thickness of at least 2 mils is recommended. With any oxidative coating, faster dry time may be obtained with increased air movement and/or higher substrate or material temperature. |
Limited Warranty: The technical data on this label or on other data is true and accurate to the best of our knowledge. We guarantee our products to conform to ANCHOR PAINT MFG. CO. quality control standards. Due to misuse in handling, storage, application and workmanship or variables such as weather or surface integrity that are beyond our control, Anchor Paint does not authorize any representative to make any warranty or merchantability of fitness of this product. Any liability whatsoever of Anchor Paint Mfg. Co. to the buyer or user of this product is limited to the purchaser’s cost of the product itself.
|